800-468-4822

image
Xtra Shield HS-714 Non Shrink

Medical-Grade USP Class VI non shrinkable tubing / sleeving that sets the standard for high-performance, safety and reliability

Developing a
new product?

Prompt short runs for custom prototype designs

500 feet for $1,500 including tooling*

*Most sizes and colors

Insultab

Heat shrink and flexible tubing specialists since 1964.

We are experienced at working with medical device manufacturers

We will manufacture to your precise specifications.

FOR PRODUCT INFORMATION AND TECHNICAL ASSISTANCE

800-468-4822
info@insultab.com

Xtra-Shield HS-714 (Non Shrink) is the preferred choice of leading medical device manufacturers world-wide for over 20 years for insulating electro-surgical instruments and for biocompatible jacketing for temporary implantation devices. download complete product Info PDF

image
  • Acrylated Olefin Tubing / Sleeving
    • Proprietary formulation — virgin polymer with no additives
  • Superior insulation integrity and reliability
    • High Dielectric Strength: 1800–2000 vpm
  • Exceptionally strong and durable
    • Superior cut-through, puncture and abrasion resistance
  • Excellent resistance to a wide range of chemicals
  • Numerous sterilization options — can be repeatedly sterilized by:
    • E-Beam and Gamma Radiation
    • Autoclave
    • ETO
    • Steris Process-Paracetic Acid
    • Hydrogen Peroxide Gas
    • Gluteraldehyde
  • Alcohol wiped and packaged as cut pieces, in coils or on plastic spools, and double plastic bagged in a clean room environment
  • Complete lot traceability
  • Meets the most stringent bio-compatible specifications:
    • USP Class VI Compliant
    • ISO-10993-5 Certified
    • USFDA Compliant
    • RoHS Compliant
  • USP Class VI and ISO 10993-5 Cytotoxicity documentation provided as post process certification when requested
  • Heat shrink version, Xtra-Shield HS-714 tubing, is also available
  • Insultab is ISO-9001:2008 Certified
  • Insultab's tubing products are Made in the USA
image

The Xtra-Shield HS-714 (Non Shrink) Difference

  • Proprietary Acrylated Olefin
  • High dielectric strength
  • Superior cut-through, puncture and abrasion resistance
  • Numerous sterilization options
  • Operating Temperature Range: -55°C to 121°C (-67°F to 250°F)
  • Physical / Electrical Properties:
    • Specific Gravity: 0.934
    • Durometer: Shore D 53
    • Tensile Strength: 3200 / 3600 psi
    • Elongation: 500 / 600%
    • Heat Shock: 168 hours @ 150° C No dripping or cracking
    • Volume Resistivity: @ 500 volts >1016
    • Dielectric Strength: 1,800 / 2,000 vpm
    • Dielectric Constant @ 1MHz: 2.0 / 2.2
    • Dissipation Factor @ 1MHz: 0.008
  • Chemical Resistance:
    • Resists a wide range of chemicals including: Hexachlorophene (pHisoHex), saline solution, povidone-iodine (Betadine), benzalkonium (Zephiran), alcohol
    • Resists moisture, UV and fungus
    AUTOCLAVE CYCLE TEST:
    20 cycles @ 121°C 15 psig for 15 min. with fast dry cycle, followed by test for:
    Property Test Method Typical Value
    Volume Resistivity @ 500 volts ASTM D 257 No change from original
    Dielectric Strength in air @ 500 kv/min rise ASTM D 149 No change from original
    Dielectric Constant @ 1 MHz ASTM D 150 No change from original
    Dissipation Factor @ 1 MHz ASTM D 150 No change from original

    Notice to User: It is imperative that manufacturers and end-users understand that the electro-surgical instruments should be placed separately, without overlay, on autoclave trays. Potential damage caused by overlay in the autoclave will significantly reduce this and any other dielectric insulator’s ability to pass the 20 cycles of autoclave required by the AAMI.

    All statements and recommendations are based on technical data that INSULTAB believes to be true and reliable. It is the responsibility of the user to determine functionality and suitability. If you have any questions on the use or handling of this product, please contact us at 800-468-4822.

  • Meets the most stringent bio-compatible specifications:
    • USP Class VI Compliant
    • ISO-10993-5 Certified
    • USFDA Compliant
    • RoHS Compliant
  • USP Class VI and ISO 10993-5 Cytotoxicity documentation provided as post process certification when requested
  • Heat shrink version, Xtra-Shield HS-714 tubing, is also available
  • Insultab is ISO-9001:2008 Certified
  • Insultab’s tubing products are Made in the USA
  • Standard Dimensions — HS-714 (Non Shrink) can be customized
      Supplied I.D. Supplied Wall Nominal Standard Packaging (per Box) Product is Supplied in Coils or on Plastic Spools
    Size in.mm in.mm Ft. / Coil or SpoolTotal Ft. / Box
    3/32 .093 2.36 .0200.51 1,000'2,000'
    1/8 .125 3.18 .0200.51 1,000'2,000'
    3/16 .187 4.75 .0200.51 1,000'2,000'
    1/4 .250 6.35 .0250.64 500'1,000'
    3/8 .375 9.53 .0250.64 200'600'
    1/2 .500 12.70 .0250.64 200'600'
  • Standard Colors — Custom colors are also available colors

  • We will manufacture to your precise specifications:
    • Custom diameters
    • Custom wall thicknesses
    • Custom cut lengths to extremely tight tolerances
    • Custom color matching
    • Custom printing with USP Class VI inks

All information presented is believed to be reliable and is offered only as a guide to product selection. As each application is unique, Insultab can make no warranties as to the suitability of any products for a particular use. Specifications are subject to change.